In Free Movement floor areas, the Material Handling Equipment travels Randomly in any direction. For Example: Wide aisle warehouse, transfer areas in Very Narrow Aisle (VNA) warehouse, factories and retail outlets.

TR-34 (3rd) Edition) - Table 4.2 & Table 4.4 (FM 2 Special): Permissible Limits on Properties II and IV in Free Movement Floors

Floor Classification
Typical Floor Use
Property II Limit (Flatness)
Property IV Limit (Levelness)
95%
100%
95%
100%
FM 1

Where very high standards of flatness amd levelness are required.

2.5
4.0
4.5
7.0
FM 2 (Special)
Floor for possible conversion to Category 1 Defined Movement.
3.0
4.5
6.5
10.0
FM 2
Building containing wide aisle racking over 8m. Free Movement and transfer areas.
3.5
5.5
8.0
12.0
FM 3
Buildings containing wide aisle racking up to 8m. Retail and manufacturing facilities
5.0
7.5
10.0
15.0

  1. For all classifications, all points surveyed should be within 15mm from datum

  2. 95% Limit - The floor is non-compliant if more than 5% of the readings or survey length exceeds the 95% limit.

  3. 100% Limit - The Floor is non-Compliant if any of the measurements exceed the 100% limit.